Kirk Cell

K-5 A

K-25

K-50

K-25 KIRK CELL

DIMENSIONS
Height to top of lid                 15 1/8”
Overall height                         16 3/4”
Width at bottom                      11 1/8”
Width at top                            12 1/16”
Depth at bottom                      9 7/16”
Depth at top                            10 1/16”

As the applied Electromagnetic Field (EMF) across the cell terminals increases, current flow through the Kirk Cell will increase in general agreement with the data in the Performance tables below. Actual current flow will vary with ambient conditions including but not limited to: temperature, solution concentration and age.


K-25 KIRK CELL PERFORMANCE TABLE

Delta E                                                                                    Apparent
Across Cell                             Resultant                                 Internal
Terminals                               Current                                    Impedance
(Volts)                                     Flow                                        (Ohms)
_______________________________________________________________

DIRECT CURRENT DATA


0.275                                       100ua                                    2750
0.47                                         1ma                                         470
0.52                                         2ma                                         260
0.56                                         3ma                                         187
0.58                                         4ma                                         145
0.63                                         5ma                                         126
0.73                                         6ma                                         122
0.79                                         7ma                                         113
0.825                                       8ma                                         103
0.85                                         9ma                                           94
0.88                                       10ma                                           88
0.94                                       15ma                                           63
1.00                                       20ma                                           50
1.08                                       25ma                                           43
1.26*                                     30ma                                           42
1.55                                      40ma                                           39
1.66                                       50ma                                           33
1.68                                     100ma                                           17
1.72                                     500ma                                             3.4
1.76                                            1A                                            1.8
1.86                                            5A                                            0.37
1.90                                         10A                                            0.19

 

ALTERNATING CURRENT DATA

0.02                                      0.5A                                           0.04
0.04                                         1A                                           0.04
0.06                                         5A                                           0.01
0.30                                         10A                                         0.03

*Leakage threshold